Patient Care Monitor Novin S 1800 – Medical Device

$0.00

12’’ screen color LED with 800*600resolution and 170-degree view angle
ECG/HR/SPO2 (Masimo) /NIBP/RESO/2TEMPs/2IBPs/ Gas & BFA modules
Capability to display 6 to 8 signal traces (only ECG:12-Leads) and 10 parameters in one page (six parameteres have been added for Rainbow parameters)
96-hours trend storage and 500 NIBP records

Description

ARR and ST Segment Analyzer sowftware and displaying numbers of PVC in a minute

Configuring parameters in different pages(Multi – page)

Drug calculation (to calculate the dose and the time of medication)

Parameters signals color selection (expect for ECG)

Rechargeable internal battery  and capability to run on AC power

Adults, Neonate, and Pediatric modes

Visual and auditory alarms

Three types of filters to eliminate cauter and environment noise

180 seconds review of ECG signal(Sigma)

Pace pulse detection and elimination

Connectibility to the central system network

VGA Output

Specific page for open-heart surgery (pump page)

Advance design of internal circuits without fan

PI(perfusion index) measurement through SPO2 probe

Quick startup

Anti-shock and Anti scratch screen

Displaying of 7 ECG Leads simultaneously

6 shortcut keys

Upgrade SPO2 Masimo to Masimo SPO2 Rainbow  in order to measure blood parameters: SpCO, PI, PVI, SpHb, SpMet, SpOc

Brain Function Assessment module (BFA)

Recording of 3 waveforms simultaneously using thermal printer

ECG 12 Leads

AWRR, Multi Gas Analyzer, Etco2 measurment

ICP measurement

Cardiac output measurement

 

CLASSIFICATION
Safety Based on IEC 60601-1, Class I, Type CF for all modules (except multi-gas & NIBP module that are BF)
Usage Continues Operation Equipment
Harmful Liquid Proof Degree Ordinary Equipment, (without Liquid Proof)
DISPLAY
Displaying TFT COLOR 800 ´ 600, 12”
Waveforms ECG,Spo2, IBP, RESP/GAS, EEG (All Freezable)
Sweep Speed 12.5, 25, 50 mm/sec
Numeric Parameters HR, PVCs, ST, SPO2, Pulse Rate, RR, T1, T2, DT, , NIBP (SYS, DIA, MAP), IBP1 (SYS, DIA, MAP), IBP2 (SYS, DIA, MAP), Co2 (EtCo2, FiCo2, AWRR), GAS (EtO2, FiO2, EtN2O,FiN2O, EtAA, FiAA), CSM (CSI%, BS%, SQI %, EMG%), Alarm Limits
Operation Method Membrane and rotary knob
ECG
Leads 3/5/12 Lead
Dynamic Range ± 5 mV
Leakage Current < 10 µA
Lead Off Current < 90 nA
Gain 4, 2, 1, 1/2, 1/4, Auto
Calibration 1mV, 0.5 sec
Filters “MONITOR” (0.5 – 28 Hz)
“NORMAL” (0.5 – 40 Hz)
“EXTENDED” (0.05 – 100 Hz)
CMRR > 98 dB
Internal Noise < 30 µV RTI
Input Impedance > 5 MOhm
QRS Detection Duration: 40 to 120 msec
Amplitude: 0.5 to 5 mV for Adult

0.2 to 5 mV for Neonate

Heart Rate Range 15 – 300 bpm for Adult

15 – 350 bpm for Neonate

Accuracy ±1 or 2 bpm
Tall T-Wave Reject up to 1.2 mV Amp.
Pace Detection / Rejection Duration: 0.1 – 2 msec
Amp: ± 2 to ± 700 mV (Without over/undershoot)
Reject From Heart Rate Counter
Re-insert into ECG to display on screen
Protection Defibrillator and Electro surgery
Standards ANSI/AAMI EC-13
Arrhythmia Analysis
Type ASYS, VFIB, VTAC, RUN, AIVR, COUPLET, BIGEMINY, TRIGEMINY, TACHY, BRADY, AFIB, PAUS, FREQUENT PVCs
Learning Rapid Learning: only 20 Seconds Required for Recognition of Dominant Rhythm
Method Real Time Arrhythmia Detection with Innovative Feature.
Memory Capability of storing the latest 80 ARR event. (waveform and Parameters)
ST Analysis
Display resolution: 0.01 mV
Measurement Rang -2mV to +2mV
Alarm Range: -2mV to +2mV
Features: User Adjustable Isoelectric and ST Point Trending of ST Values
Update period: 5 Sec.
SPO2 (MASIMO Rainbow SET )
Method 2 Wave Length Pulse Wave Type
Range Spo2 0 – 100%

SpMet 0 – 99.9%

SpCo 0 – 99%

SpHb 0 – 25 g/dl

SpOC 0 – 35 ml/dl

PR 25 – 240 bmp

PI 0.02 – 20%

PVI 0 – 100%

Accuracy Oxygen saturation

During no motion conditions: Adult: ±3% (SPO2 60 ~ 80%)

±2% (SPO2 70 ~ 100%)

Neonate: 3% (SPO2 70 ~ 100%)

During motion conditions: ±3% (SPO2 70 ~ 100%)

During low perfusion conditions: ±2% (SPO2 70 ~ 100%)

Pulse Rate

During no motion conditions: ±3 bpm

During motion conditions: ±5 bpm

During low perfusion conditions: ±3 bpm

Carboxyhemoglobin Saturation: Adult: 1% – 40% ±3%

Methemoglobin Saturation 1% – 15% ±1%

Total Hemoglobin Adult: 8 – 17 g/dL ±1g/dL

NIBP 
Measurement method Oscillometric
Measurement mode Manual/Automatic(intervals between 1min-24hour) / STAT
Measurement time 20-25 sec (excluding cuff pressurization time)
Measurement Range Adult: SYS 30 ~ 255 mmHg
DIA 15 ~ 220 mmHg
MAP 20 ~ 235 mmHg
Neonate: SYS 30 ~ 135 mmHg
DIA 15 ~ 110 mmHg
MAP 20 ~ 125 mmHg
Pressure Transducer accuracy ±3 mmHg full range
Initial Inflation Target Adult 150 mmHg , Neonate 85 mmHg
Overall System Efficacy ANSI/AAMI SP-10/2002
Memory 500 Records
IBP (optional)
Channel 2 Channels
Measurement Range SYS -50 ~300 mmHg
DIA -50 ~ 300 mmHg
MAP -50 ~ 300 mmHg
Pressure sensor sensitivity 5 μV / V / mmHg
Pressure sensor Impedance 300-2500 ohm
Resolution 1 mmHg
Accuracy 1 % or 1mmHg (every one which is more)Excluded Transducer
Alarm Range 20-300 mmHg
Filters Adjustable 8, 16, 22 Hz

 

CO2 Main Stream (Optional)
Method Infra-red absorption
Measuring Parameters EtCo2, FiCo2, AWRR
Measuring range Co2 0 – 15%

AWRR 0-150 BrPM

Accuracy Co2 ±(0.2 V% + 2% of reading)

AWRR ± 1BrPM

CO2 side- Stream (Optional)
Method Infra-red absorption
Measuring Parameters EtCo2, FiCo2, AWRR
Measuring range Co2 0 – 15%

AWRR 0-150 BrPM

Accuracy Co2 ±(0.2 V% + 2% of reading)

AWRR ± 1BrPM

Multi gas Main Stream (Optional)
Method Infra-red absorption
Oxygen sensor type Ultrafast response time galvanic oxygen sensor.
Measuring Parameters CO2,O2,N2O, Anesthesia Agent(HAL,ISO,ENF,SEV,DES), AWRR
Measuring range, Accuracy CO2 010% ±(0.2 V% + 2% of reading)

1015% ±(0.3 V% + 2% of reading)

NO2 0-100% ±(0.2 V% + 2% of reading)

HAL, ISO, ENF 0-8% ±(0.15 V% + 5% of reading)

SEV 0-10% ±(0.15 V% + 5% of reading)

DES 0-22% ±(0.15 V% + 5% of reading)

O2 0-100% ±(1 V% + 2% of reading)

AWRR 0-150BrPM ±1BrPM

Multi gas side- Stream (Optional)
Method Infra-red absorption
Oxygen sensor type Ultrafast response time galvanic oxygen sensor.
Measuring Parameters CO2,O2,N2O, Anesthesia Agent(HAL,ISO,ENF,SEV,DES), AWRR
Measuring range, Accuracy CO2 015% ±(0.2 V% + 2% of reading)

NO2 0-100% ±(0.2 V% + 2% of reading)

HAL, ISO, ENF 0-8% ±(0.15 V% + 5% of reading)

SEV 0-10% ±(0.15 V% + 5% of reading)

DES 0-22% ±(0.15 V% + 5% of reading)

O2 0-100% ±(1 V% + 2% of reading)

AWRR 0-150BrPM ±1BrPM

Cerebral State Monitor (optional)
Function Measure the direct effect of anesthesia and sedative drugs on brain
Measuring parameters CSI%, BS%, SQI%, EMG (Bar)
Waveform EEG
connection Wireless
RESPIRATION
Method Impedance
Base Resistance 250 – 1250 Ohm
Dynamic Range 0.2 – 2 Ohm
Breath Rate Range 6 – 150 BrPM
TEMPERATURE
Probe Type YSI 400 Compatible
Range 0 – 50 °C
Accuracy ± 0.2 °C
ALARM
Sources Error messages, all other Parameter Limits
Alarm On / Off Selectable for All Parameters
Alert Blinking on Display,
Volume Selectable Audio Alarms, Light indicator
TREND
Sources HR,PVCs,ST,SPO2, RR, T1, T2,

IBP1(SYS,DIA,MAP) , IBP2(SYS,DIA,MAP), EtCo2, FiCo2, AWRR, EtO2 , FiO2, EtN2O, FiN2O, EtAA, FiAA(ISO, DES ,ENF , HAL ,SEV)

Trend Time 15, 30, 45 Min, 1, 2, 4, 8, 12, 16,24,36, 48, 72, 96 Hours
Resolution 1 sec
INPUT/OUTPUT
Network Digital, Serial, RS422, Full Duplex
Connection Up to 16 BEDs to one CENTRAL
GENERAL
Safety Based on IEC 60601-1
Protection Against Electro surgery and Defibrillator
AC Power 90 – 240 VAC, 50/60 Hz
Internal Battery Sealed Lead Acid, Rechargeable, 12 V, 3.3 AH

Charge Time: 16 Hours

Usage: 120 min (Full charge)

DC Power Plug 12 – 14V – 3A / (6A with recorder)
Dimension (cm) 31 (W) ´ 28 (H) ´ 19 (D)
Weight 6 Kg (approximately)
RECORDER (Optional)
Model SAADAT Thermal Printer
Printing Speed 6, 12.5, 25, 50 mm/sec
Paper 58 mm by 100 foot roll
ENVIRONMENTAL
Temperature Operating : 5 to 40°C (For Gas Module: 10 to 35°C)

Storage : -20 to 60°C (For Gas Module: -20 to 50°C)

Humidity 20-90% (Non condensing)
Altitude -200 to 3000m
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Patient Care Monitor Novin S 1800 – Medical Device”

Your email address will not be published. Required fields are marked *

Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.

Company Policies
Inquiries

General Inquiries

There are no inquiries yet.