Patient Care Monitor Zagros S – Medical Device

$0.00

12’’ screen color LED with 800*600resolution and 170-degree view angle

ECG/HR/SPO2 (Masimo) /NIBP/RESO/2TEMPs/2IBPs/ Gas & BFA  modules

Capability to display 6 to 8 signal traces (only ECG:12-Leads) and 10 parameters in one page (six parameteres have been added for Rainbow parameters)

96-hours trend storage and 500 NIBP records

Description

ARR and ST Segment Analyzer sowftware and displaying numbers of PVC in a minute

Configuring parameters in different pages(Multi – page)

Drug calculation (to calculate the dose and the time of medication)

Parameters signals color selection (expect for ECG)

Rechargeable internal battery  and capability to run on AC power

Adults, Neonate, and Pediatric modes

Visual and auditory alarms

Three types of filters to eliminate cauter and environment noise

180 seconds review of ECG signal(Sigma)

Pace pulse detection and elimination

Connectibility to the central system network

VGA Output

Specific page for open-heart surgery (pump page)

Advance design of internal circuits without fan

PI(perfusion index) measurement through SPO2 probe

Quick startup

Anti-shock and Anti scratch screen

Displaying of 7 ECG Leads simultaneously

10 shortcut keys

Upgrade SPO2 Masimo to Masimo SPO2 Rainbow  in order to measure blood parameters: SpCO, PI, PVI, SpHb, SpMet, SpOc

Touch screen

Brain Function Assessment module (BFA)

Upgrading 2IBPs To 4IBPs

Recording of 3 waveforms simultaneously using thermal printer

ECG 12 Leads

AWRR, Multi Gas Analyzer, Etco2 measurment

ICP measurement

Cardiac output measurement

Controlling system by rotary knob &Keyboard and touch screen simultaneously

 

CLASSIFICATION
SafetyBased on IEC 60601-1, Class I, Type CF for all modules (except multi-gas & NIBP module that are BF)
UsageContinues Operation Equipment
Harmful Liquid Proof DegreeOrdinary Equipment, (without Liquid Proof)
DISPLAY
DisplayingTFT COLOR 800 ´ 600, 12”
WaveformsECG,Spo2,RESP/GAS, IBP, EEG (All Freezable)
Sweep Speed12.5, 25, 50 mm/sec
Numeric ParametersHR, PVCs, ST, SPO2, Pulse Rate, RR, T1, T2, DT, Co2 (EtCo2, FiCo2, AWRR), NIBP (SYS, DIA, MAP), IBP1 (SYS,DIA,MAP), IBP2 (SYS,DIA,MAP), IBP3 (SYS,DIA,MAP), IBP4 (SYS,DIA,MAP), Alarm Limits, GAS (EtO2, FiO2, EtN2O,FiN2O, EtAA, FiAA), CSM (CSI%, BS%, SQI%, EMG%)
Operation MethodMembrane and rotary knob
ECG
Leads3/5/12 Leads
Dynamic Range± 5 mV
Leakage Current< 10 µA
Lead Off Current< 90 nA
Gain4, 2, 1, 1/2, 1/4, Auto
Calibration1mV, 0.5 sec
Filters“MONITOR” (0.5 – 28 Hz)
“NORMAL” (0.5 – 40 Hz)
“EXTENDED” (0.05 – 100 Hz)
CMRR> 98 dB
Internal Noise< 30 µV RTI
Input Impedance> 5 Mohm
QRS DetectionDuration: 40 to 120 msec
Amplitude: 0.5 to 5 mV for Adult

0.2 to 5 mV for Neonate

Heart Rate Range15 – 300 bpm for Adult

15 – 350 bpm for Neonate

Accuracy± 1% or 2 bmp
Tall T-WaveReject up to 1.2 mV Amp.
Pace Detection / RejectionDuration: 0.1 – 2 msec
Amp: ± 2 to ± 700 mV (Without over/undershoot)
Reject From Heart Rate Counter
Re-insert into ECG to display on screen
ProtectionDefibrillator and Electro surgery
StandardsANSI/AAMI EC-13
Arrhythmia Analysis
TypeASYS, VFIB, VTAC, RUN, AIVR, COUPLET, BIGEMINY, TRIGEMINY, TACHY, BRADY, AFIB, PAUS, FREQUENT PVCs
LearningRapid Learning: only 20 Seconds Required for Recognition of Dominant Rhythm
MethodReal Time Arrhythmia Detection with Innovative Feature.
MemoryCapability of storing the latest 80 ARR event. (waveform and Parameters)
ST Analysis
Display resolution:0.01 mV
Measurement Rang-2mV to +2mV
Alarm Range:-2mV to +2mV
Features:User Adjustable Isoelectric and ST Point Trending of ST Values
Update period:5 Sec.
SPO2 (MASIMO Rainbow SET )
Method2 Wave Length Pulse Wave Type
RangeSpo2 0 – 100%

SpMet 0 – 99.9%

SpCo 0 – 99%

SpHb 0 – 25 g/dl

SpOC 0 – 35 ml/dl

PR 25 – 240 bmp

PI 0.02 – 20%

PVI 0 – 100%

AccuracyOxygen saturation

During no motion conditions: Adult: ±3% (SPO2 60 ~ 80%)

±2% (SPO2 70 ~ 100%)

Neonate: 3% (SPO2 70 ~ 100%)

During motion conditions: ±3% (SPO2 70 ~ 100%)

During low perfusion conditions: ±2% (SPO2 70 ~ 100%)

Pulse Rate

During no motion conditions: ±3 bpm

During motion conditions: ±5 bpm

During low perfusion conditions: ±3 bpm

Carboxyhemoglobin Saturation: Adult: 1% – 40% ±3%

Methemoglobin Saturation 1% – 15% ±1%

Total Hemoglobin Adult: 8 – 17 g/dL ±1g/dL

NIBP
Measurement methodOscillometric
Measurement modeManual/Automatic(intervals between 1min-24hour) / STAT
Measurement time20-25 sec (excluding cuff pressurization time)
Measurement RangeAdult: SYS 30 ~ 255 mmHg
DIA 15 ~ 220 mmHg
MAP 20 ~ 235 mmHg
Neonate: SYS 30 ~ 135 mmHg
DIA 15 ~ 110 mmHg
MAP 20 ~ 125 mmHg
Pressure Transducer accuracy±3 mmHg full range
Initial Inflation Target

Overall System Efficacy

Adult 150 mmHg , Neonate 85 mmHg
ANSI/AAMI SP-10/2002
Memory500 Records
IBP (optional)
Channel2 Channels (Up to 4)
Measurement RangeSYS -50 ~ 300 mmHg
DIA -50 ~ 300 mmHg
MAP -50 ~ 300 mmHg
Pressure sensor sensitivity5 μV / V / mmHg
Pressure sensor Impedance300-2500 ohm
Resolution1 mmHg
Accuracy1 % or 1mmHg (every one which is more)Excluded Transducer
Alarm Range20-300 mmHg
FiltersAdjustable 8, 16, 22 Hz

 

CO2 Main Stream (Optional)
MethodInfra-red absorption
Measuring ParametersEtCo2, FiCo2, AWRR
Measuring rangeCo2 0 – 15%

AWRR 0-150 BrPM

AccuracyCo2 ± (0.2v% + 2% of reading)

AWRR ± 1BrPM

CO2 side- Stream (Optional)
MethodInfra-red absorption
Measuring ParametersEtCo2, FiCo2, AWRR
Measuring rangeCo2 0 – 15%

AWRR 0-150 BrPM

AccuracyCo2 ±(0.2 V% + 2% of reading)

AWRR ± 1BrPM

Multi gas Main Stream (Optional)
MethodInfra-red absorption
Oxygen sensor typeUltrafast response time galvanic oxygen sensor.
Measuring ParametersCO2,O2,N2O, Anesthesia Agent(HAL,ISO,ENF,SEV,DES), AWRR
Measuring range, AccuracyCO2 010% ±(0.2 V% + 2% of reading)

1015% ±(0.3 V% + 2% of reading)

NO2 0-100% ±(0.2 V% + 2% of reading)

HAL, ISO, ENF 0-8% ±(0.15 V% + 5% of reading)

SEV 0-10% ±(0.15 V% + 5% of reading)

DES 0-22% ±(0.15 V% + 5% of reading)

O2 0-100% ±(1 V% + 2% of reading)

AWRR 0-150BrPM ±1BrPM

Multi gas side- Stream (Optional)
MethodInfra-red absorption
Oxygen sensor typeUltrafast response time galvanic oxygen sensor.
Measuring ParametersCO2,O2,N2O, Anesthesia Agent(HAL,ISO,ENF,SEV,DES), AWRR
Measuring range, AccuracyCO2 015% ±(0.2 V% + 2% of reading)

NO2 0-100% ±(0.2 V% + 2% of reading)

HAL, ISO, ENF 0-8% ±(0.15 V% + 5% of reading)

SEV 0-10% ±(0.15 V% + 5% of reading)

DES 0-22% ±(0.15 V% + 5% of reading)

O2 0-100% ±(1 V% + 2% of reading)

AWRR 0-150BrPM ±1BrPM

Cerebral State Monitor (optional)
FunctionMeasure the direct effect of anesthesia and sedative drugs on brain
Measuring parametersCSI%, BS%, SQI%, EMG (Bar)
WaveformEEG
connectionWireless
RESPIRATION
MethodImpedance
Base Resistance250 – 1250 Ohm
Dynamic Range0.2 – 2 Ohm
Breath Rate Range6 – 150 BrPM
TEMPERATURE
Probe TypeYSI 400 Compatible
Range0 – 50 °C
Accuracy± 0.2 °C
ALARM
SourcesError messages, all other Parameter Limits
Alarm On / OffSelectable for All Parameters
AlertBlinking on Display,
Volume Selectable Audio Alarms, Light indicator
TREND
SourcesHR,PVCs,ST,SPO2, RR, T1, T2,

IBP1(SYS,DIA,MAP) , IBP2(SYS,DIA,MAP) , IBP3(SYS,DIA,MAP) , IBP4(SYS,DIA,MAP) , EtCo2,FiCo2,AWRR, EtO2, FiO2

, EtN20,FiN2O,,EtAA,FiAA(ISO, DES ,ENF , HAL ,SEV)

Trend Time15, 30, 45 Min, 1, 2, 4, 8, 12, 16, 24,36, 48, 72, 96 Hours
Resolution1 sec
INPUT/OUTPUT
NetworkDigital, Serial, RS422, Full Duplex
ConnectionUp to16 BEDs to one CENTRAL
GENERAL
SafetyBased on IEC 60601-1
ProtectionAgainst Electro surgery and Defibrillator
AC Power90 – 240 VAC, 50/60 Hz
Internal BatterySealed Lead Acid, Rechargeable, 12 V, 3.3 AH

Charge Time: 16 Hours

Usage: More than 1 Hour (Full charge)

DC Power Plug12 – 14V – 3A / (6A with recorder)
Dimension (cm)32 (W) ´ 30 (H) ´ 19 (D)
Weight6 Kg (approximately)
RECORDER (Optional)
ModelSAADAT Thermal Printer
Printing Speed6, 12.5, 25, 50 mm/sec
Paper58 mm by 100 foot roll
ENVIRONMENTAL
TemperatureOperating : 5 to 40°C (For Gas Module: 10 to 35°C)

Storage : -20 to 60°C (For Gas Module: -20 to 50°C)

Humidity20-90% (Non condensing)
Altitude-200 to 3000m

 

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Patient Care Monitor Zagros S – Medical Device”

Your email address will not be published. Required fields are marked *

Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.

Company Policies
Inquiries

General Inquiries

There are no inquiries yet.