Patient Care Monitor Alborz B9 – Medical Device

$0.00

18.5’’ screen color LED with 1366*768 resolution and 170-degree view angle
ECG/HR/SPO2 (Masimo) /NIBP/RESO/2TEMPs/2IBPs/ Interface CO2, Gas and BFA modules
Capability to display 6 to 8 signal traces (only ECG:12-Leads) and 10 parameters in one page (six parameteres have been added for Rainbow parameters)
96-hours trend storage and 500 NIBP records

Category:
Description

ALARM RECALL (Displaying occurred alarms along with ECG/SPO2/2IBPs/RESP/GAS Waveforms)
ARR and ST Segment Analyzer sowftware and displaying numbers of PVC in a minute
Configuring parameters in different pages(Multi – page)
Drug calculation (to calculate the dose and the time of medication)
Parameters signals color selection (expect for ECG)
Displaying of OXY-CRG
Rechargeable internal battery  and capability to run on AC power
Adults, Neonate, and Pediatric modes
Visual and auditory alarms
Three types of filters to eliminate cauter and environment noise
260 seconds review of ECG signal(Sigma)
Pace pulse detection and elimination
Connectibility to the central system network
VGA Output

 

CLASSIFICATION

Safety

Usage

Based on IEC 60601-1, Class I, Type CF for all modules (except Multi-gas & NIBP module that are BF)

Continues Operation Equipment

Harmful Liquid Proof Degree

Ordinary Equipment, (without Liquid Proof)

DISPLAY

B9 Display

TFT COLOR 1366 ´ 768, 18.5”

Waveforms

ECG, SPO2, IBP, RESP/GAS,EEG (All Freezable)

Sweep Speed

12.5, 25, 50 mm/sec

Numeric Parameters

HR,PVCs,ST,SPO2, Pulse Rate, NIBP (SYS, DIA, MAP) ,

IBP1(SYS,DIA,MAP) ,IBP2(SYS,DIA,MAP), IBP3(SYS,DIA,MAP), IBP4(SYS,DIA,MAP),RR, T1, T2, DT, EtCo2, FiCo2, AWRR,EtN2O,FiN2O,EtO2, FiO2,EtAA,FiAA,CSI,BS%,EMG%,SQI%

Operation Method

Membrane and rotary knob , Touch Screen (Optional)

ECG

Leads

3/5/12 leads

Dynamic Range

± 5 mV

Leakage Current

< 10 µA

Lead Off Current

< 90 nA

Gain

4, 2, 1, 1/2, 1/4, Auto

Calibration

1mV, 0.5 sec

Filters

“MONITOR” (0.5 – 28 Hz)

“NORMAL” (0.5 – 40 Hz)

“EXTENDED” (0.05 – 100 Hz)

CMRR

> 98 dB

Internal Noise

< 30 µV RTI

Input Impedance

> 5 Mohm

QRS Detection

Duration: 40 to 120 msec

Amplitude: 0.25 to 5 mV for Adult

0.2 to 5 mV for Neonate

Heart Rate Range

15 – 300 bpm for Adult

15 – 350 bpm for Neonate

Accuracy

±1% or 2 bpm

Tall T-Wave

Reject up to 1.2 mV Amp.

Pace Detection / Rejection

Duration: 0.1 – 2 msec

Amp: ± 2 to ± 700 mV (Without over/undershoot)

Reject From Heart Rate Counter

Re-insert into ECG to display on screen

Protection

Defibrillator and Electro surgery

Standards

ANSI/AAMI EC-13

Arrhythmia Analysis

Type

ASYS, VFIB, VTAC, RUN, AIVR, COUPLET, BIGEMINY, TRIGEMINY, TACHY, BRADY,AFIB, PAUS, FREQUENT PVCs

Learning

Rapid Learning: only 20 Seconds Required or Recognition of Dominant Rhythm

Method

Real Time Arrhythmia Detection with Innovative Feature.

Memory

Capability of storing the latest 80 ARR event. (waveform and Parameters)

ST Analysis

Display resolution:

0.01 mV

Measurement Rang

-2mV to +2mV

Alarm Range:

-2mV to +2mV

Features:

User Adjustable Isoelectric and ST Point Trending of ST Values

Update period:

5 Sec.

SPO2 (MASIMO Rainbow SET )

Method

2 Wave Length Pulse Wave Type

Range

Spo2 0 – 100%

SpMet 0 – 99.9%

SpCo 0 – 99%

SpHb 0 – 25 g/dl

SpOC 0 – 35 ml/dl

PR 25 – 240 bmp

PI 0.02 – 20%

PVI 0 – 100%

Accuracy

Oxygen saturation

During no motion conditions: Adult: ±3% (SPO2 60 ~ 80%)

±2% (SPO2 70 ~ 100%)

Neonate: 3% (SPO2 70 ~ 100%)

During motion conditions: ±3% (SPO2 70 ~ 100%)

During low perfusion conditions: ±2% (SPO2 70 ~ 100%)

Pulse Rate

During no motion conditions: ±3 bpm

During motion conditions: ±5 bpm

During low perfusion conditions: ±3 bpm

Carboxyhemoglobin Saturation: Adult: 1% – 40% ±3%

Methemoglobin Saturation 1% – 15% ±1%

Total Hemoglobin Adult: 8 – 17 g/dL ±1g/dL

NIBP 

Measurement method

Oscillometric

Measurement mode

Manual/Automatic(intervals between 1min-24hour) / STAT

Measurement time

20-25 sec (excluding cuff pressurization time)

Measurement Range

Adult: SYS 30 ~ 255 mmHg

DIA 15 ~ 220 mmHg

MAP 20 ~ 235 mmHg

Neonate: SYS 30 ~ 135 mmHg

DIA 15 ~ 110 mmHg

MAP 20 ~ 125 mmHg

Pressure Transducer accuracy

±3 mmHg full range

Initial Inflation Target

Adult 150 mmHg , Neonate 85 mmHg

Overall System Efficacy

ANSI/AAMI SP-10/2002

Memory

500 Records

IBP (optional)

Channel

2 Channels (Up to 4)

Measurement Range

SYS -50 ~ 300 mmHg

DIA -50 ~ 300 mmHg

MAP -50 ~ 300 mmHg

Pressure sensor sensitivity

5 μV / V / mmHg

Pressure sensor Impedance

300-2500 ohm

Resolution

1 mmHg

Accuracy

1 % or 1mmHg (every one is which is more)Without Transducer

Filters

Adjustable 8, 16, 22 Hz

CO2 Main Stream (Optional)

Method

Infra-red absorption

Measuring Parameters

EtCo2, FiCo2, AWRR

Measuring range

Co2 0 – 15%

AWRR 0-150 BrPM

Accuracy

Co2 ±(0.2 V% + 2% of reading)

AWRR ± 1BrPM

CO2 side- Stream (Optional)

Method

Infra-red absorption

Measuring Parameters

EtCo2, FiCo2, AWRR

Measuring range

Co2 0 – 15%

AWRR 0-150 BrPM

Accuracy

Co2 ±(0.2 V% + 2% of reading)

AWRR ± 1BrPM

Multi gas Main Stream (Optional)

Method

Infra-red absorption

Oxygen sensor type

Ultrafast response time galvanic oxygen sensor.

Measuring Parameters

CO2,O2,N2O, Anesthesia Agent(HAL,ISO,ENF,SEV,DES), AWRR

Measuring range, Accuracy

CO2 010% ±(0.2 V% + 2% of reading)

1015% ±(0.3 V% + 2% of reading)

NO2 0-100% ±(0.2 V% + 2% of reading)

HAL, ISO, ENF 0-8% ±(0.15 V% + 5% of reading)

SEV 0-10% ±(0.15 V% + 5% of reading)

DES 0-22% ±(0.15 V% + 5% of reading)

O2 0-100% ±(1 V% + 2% of reading)

AWRR 0-150BrPM ±1BrPM

Multi gas side- Stream (Optional)

Method

Infra-red absorption

Oxygen sensor type

Ultrafast response time galvanic oxygen sensor.

Measuring Parameters

CO2,O2,N2O, Anesthesia Agent(HAL,ISO,ENF,SEV,DES), AWRR

Measuring range, Accuracy

CO2 015% ±(0.2 V% + 2% of reading)

NO2 0-100% ±(0.2 V% + 2% of reading)

HAL, ISO, ENF 0-8% ±(0.15 V% + 5% of reading)

SEV 0-10% ±(0.15 V% + 5% of reading)

DES 0-22% ±(0.15 V% + 5% of reading)

O2 0-100% ±(1 V% + 2% of reading)

AWRR 0-150BrPM ±1BrPM

Cerebral State Monitor (optional)

Function

Measure the direct effect of anesthesia and sedative drugs on brain

Measuring parameters

CSI%, BS%, SQI%, EMG (Bar)

Waveform

EEG

connection

Wireless

RESPIRATION

Method

Impedance

Base Resistance

250 – 1250 Ohm

Dynamic Range

0.2 – 2 Ohm

Breath Rate Range

6 – 150 BrPM

TEMPERATURE

Probe Type

YSI 400 Compatible

Range

0 – 50 °C

Accuracy

± 0.2 °C

ALARM

Sources

Error messages, all other Parameter Limits

Alarm On / Off

Selectable for All Parameters

Alert

Blinking on Display,

Volume Selectable Audio Alarms, Light indicator

TREND

Sources

HR,PVCs,ST,SPO2, RR, T1, T2,

IBP1(SYS,DIA,MAP) , IBP2(SYS,DIA,MAP), IBP3(SYS,DIA,MAP), IBP4(SYS,DIA,MAP), EtCo2, FiCo2, AWRR, EtN20, FiN2O, EtO2, FiO2, EtAA, FiAA (ISO, DES ,ENF , HAL ,SEV)

Trend Time

15, 30 , 45 Min, 1, 2, 4, 8, 12,16, 24,36, 48, 72, 96 Hours

Resolution

1 sec

INPUT/OUTPUT

Network

Digital, Serial, Full Duplex

Connection

Up to 16 BEDs to one CENTRAL

GENERAL

Safety

Based on IEC 60601-1

Protection

Against Electro surgery and Defibrillator

AC Power

90 – 240 VAC, 50/60 Hz

Internal Battery

Lithium polymer, 11.1 V , 4 AH

Charge Time: 16 Hours

Usage: More than 3 Hours (Full Charge)

DC Power Plug

12 – 14V – 3A / (6A with recorder)

Dimension (cm)

45 (W) ´ 35 (H) ´ 16 (D)

Weight

7 Kg (approximately)

RECORDER (Optional)

Model

SAADAT Thermal Printer

Printing Speed

6,12.5, 25, 50 mm/sec

Paper

58mm by 100 foot roll

ENVIRONMENTAL

Temperature

Operating : 5 to 40°C (For Gas Module: 10 to 35°C)

Storage : -20 to 60°C (For Gas Module: -20 to 50°C)

Humidity

20-90% (Non condensing)

Altitude

-200 to 3000m

   

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Patient Care Monitor Alborz B9 – Medical Device”

Your email address will not be published. Required fields are marked *

Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.

Company Policies
Inquiries

General Inquiries

There are no inquiries yet.