Ventilator – Medical Device

$0.00

Pediatric through adult (20 ml Tidal volume)

12’’ color touch screen

Ergonomic design helps to do better

Use for invasive and non-invasive

Automatic set-out raspiratory parameters by IBW determination

Description

72 hours trend storage

Smart alarm system

Capability to stay on for 2 hours with internal Battery

Automatic leak compensation

Automatic tube compensation

Modern pressure and flow trigger

 

Technical Specification
Ventilation ModesAssisted Control Mandatory VentilationCMV
Synchronized Intermittent Mandatory VentilationSIMV
Spontaneous VentilationSPONT
Breath TypesVolume–controlled breathsV–CMV, V–SIMV
Pressure–controlled breathsP–CMV, P–SIMV, PS
Volume Targeted Pressure–controlled breaths (Pressure Regulated Volume Control) & (Volume Support)PRVC–CMV,PRVC–SIMV,VS
Dual Level PEEP breaths (Spontaneous Positive Airway Pressure)SPAP
Patient Height42 – 250 cm
IBW  (Ideal Body Weight )5–200 Kg
GenderMale, Female
VBS (Ventilator Breathing System)Acceptable Compliance range0.5 – 5 ml/cmH2O
Acceptable Inspiratory Resistance range0 – 2.5 cmH2O.s/l
Acceptable Expiratory Resistance range0 – 2.5 cmH2O.s/l
Apnea BackupSettingsOn (Rate, Pcontrol,Ti);  OFF
Breath triggeringPressure triggering(-2) – (-20) cmH2O
Flow triggering2 – 20 l/min
Additional SettingRespiratory Rate

Accuracy:±1 b/min or 4% wig

2– 120 b/min
Tidal Volume

Accuracy:

For 50–2000 ml:  ± (4 ml + 15% Actual reading)

For 20–49 ml:      ± (7 ml + 15% Actual reading)

20 – 2000 ml

(Compliance & BTPS compensated)

PEEP / CPAP

Accuracy:±12% or ±(2cmH2O +4% Actual reading)  wig

0 – 40 cmH2O
Pcontrol

Accuracy: ±12% or ±(2cmH2O +4% Actual reading)  wig

2 – 80 cmH2O
Psupport

Accuracy: ±12% or ±(2cmH2O +4% Actual reading)  wig

0 –60cmH2O
Peak Flow

Accuracy: ±12% or ±(3 l/min +4% Actual reading) wig

Mandatory

3– 120 l/min

Spontaneous

1 –200l/min

Leak Comp

Automatic Leak Compensation

On or Off
Base Flow4.5 – 25 l/min
Flow PatternsSquare, Dec, Dec 50%
NIVOn or Off

Non–Invasive ventilation can be enabled in all modes.

I–Time (Ti)

Accuracy: ± 0.02 sec

0.2 – 5.0 sec
Pause (insp plateau)

Accuracy:  ±0.02 sec

0.0 – 2.0 sec
Rise timeFast, Med, Slow
Exhalation sensitivity

Accuracy: ±12% or ±(3 l/min +4% Actual reading) wig

10–80 % of peak flow
Oxygen (FiO2)

Accuracy (Delivery): ± (3 %) full scale

21 – 100 %
Nebulizer

Accuracy:  ±10 s

On or Off;

User selected duration (1–480 minutes)

User selected interval (1–480 minutes)

SighOn or Off; 0 – 50% of volume or pressure setting

Interval; 20 – 200 breaths

Sighs per time: 1 – 6

Humidification TypeNone, HME, Warm Humidified
Compliance CompOn or Off
Graph SettingsWaveforms; up to 3 (flow, pressure, volume)

Loops; 1 or 2

Trend Data SettingsUp to 3 trends
Displayed Measurements6
Compliance CompensationOn or Off
Audio/Display SettingsAudio Level

LCD Brightness

SPAP Mode SettingsPhigh

Accuracy:±12% or ±(2cmH2O +4% Actual reading)  wig

5 to 50 cmH2O
Plow

Accuracy: ±12% or ±(2cmH2O +4% Actual reading)  wig

0 to 50 cmH2O
Psup High

Accuracy: ±12% or ±(2cmH2O +4% Actual reading)  wig

Phigh + Psup High will not exceed 80 cmH2O

0 to 75cmH2O
Psup Low

Accuracy: ±12% or ±(2cmH2O +4% Actual reading)  wig

Plow + Psup Low will not exceed 80 cmH2O

0 to 80 cmH2O
Thigh

Accuracy:  ±0.02 sec

(Thigh+Tlow ≤ 60 sec)

0.1 to 59.8 sec
Tlow

Accuracy:  ±0.02 sec

(Thigh+Tlow ≤ 60 sec)

0.2 to 59.9 sec
Monitored / Displayed Patient ValuesPressure Values
Ppeak (peak pressure during a breath)

Accuracy: ±12% or ±(2cmH2O +4% Actual reading)  wig

0 – 100 cmH2O
PEEP (pressure at end exhalation)

Accuracy: ±12% or ±(2cmH2O +4% Actual reading)  wig

0 –100cmH2O
Pmean (averaged mean pressure)

Accuracy: ±12% or ±(2cmH2O +4% Actual reading)  wig

0 – 100 cmH2O
PendInsp

Accuracy: ±12% or ±(2cmH2O +4% Actual reading)  wig

0 – 100 cmH2O
Volume / Flow Values
Vte (expiratory tidal volume)

Accuracy: ±(4 ml + 15% Actual reading)

0 – 3000 ml
Vti

Accuracy: ±(4 ml + 15% Actual reading)

0 – 3000 ml
Ve (exhaled minute volume)

Accuracy: ±12 % or ±(2 L+ 4% Actual reading)  wig

0 –99l/min
VeSpont (spontaneous exhaled minute volume)Accuracy: ±12 % or ±(2 L+ 4% Actual reading)  wig0 –99l/min
Leak

Accuracy: ±12 %  or ±(3% + 4% Actual reading)  wig

0 – 100%
PF (peak inspiratory flow)

Accuracy: ±12% or ±(3 l/min +4% Actual reading) wig

0 – 200 l/min
PFe (peak expiratory  flow)

Accuracy: ±12% or ±(3 l/min +4% Actual reading) wig

0 – 160  l/min
Time Values
Rate (measured mandatory and spontaneous breaths per minute)

Accuracy: ±1 b/min or 4% wig

0 – 150 b/min
Rate Sp.

Accuracy: ±1 b/min or 4% wig

0 – 150 b/min
Inspiration Time (Ti)

Accuracy: ± 0.2 sec

0.1   99.9 sec
Expiratory Time (Te)

Accuracy: ± 0.2 sec

0.1   99.9 sec
I:E, calculated only1:99 – 99:1
H:L1:599 – 299:1
Ti/Ttot

Accuracy: ±5% or ±1 wig

1 – 99.9%
Respiratory Mechanics
Cstat

(static compliance, lung stiffness)

Accuracy: ±10% or ±4 ml/cmH2O wig

0 – 250ml/cmH2O
Cdyn

(Dynamic compliance)

0 – 250 ml/cmH2O
Rinsp

(resistance of airways and tubes)

0 – 1000 cmH2O/l/sec
Rexp

(Expiratory resistance)

0 – 1000 cmH2O/l/sec
Auto PEEP (Actual PEEP – set PEEP)

Accuracy: ±12% or ±(2cmH2O +4% Actual reading)  wig

0 – 100 cmH2O
Pplateau

Accuracy: ±12% or ±(2cmH2O +4% Actual reading)  wig

0 – 100 cmH2O
RSBI

(Measured breathing rate divided by Insp tidal volume) (RR/Vt = RSBI)

Accuracy: ±10% or ±40 b/min/l   wig

0 – 3000 b/min/l
O2

Accuracy (Delivery): ±3 %

Response time < 30 s

15 – 103%
P0.1

(The maximal slope of the airway pressure drop during the first 100 ms when the airway is occluded.)

Accuracy: ± (2 cmH20 + 4%)

-30 – 0 cmH2O
NIF

(The maximum negative pressure generated during inspiration against an occluded airway)

Accuracy: ± (2 cmH20 + 4%)

-60 – 0 cmH2O
P0.1/NIF0 – 100 %
WOBimp

(Work of breathing)

Accuracy: ± 10% Actual reading

0 – 20 j/l
RCe

(Expiratory time constant)

0 – 99.9 Sec
C20/C

(Compliance ratio)

0.00 – 5.00
Real Time Curves
Pressure + Time , Flow + Time , Volume + TimePressure over time, Flow over time, Volume over time
P–V Loop, F–V LoopPressure–volume loop, Flow–volume loop
Performing ProceduresInspiration-HoldPause the ventilator at end inspiration

Maximum allowable duration shall be 20 sec

Expiration-HoldPause the ventilator in expiration

Maximum allowable duration shall be 20 sec

Manual BreathingDelivery a mandatory breath during the next expiratory breath in all mode
P0.1The maximal slope of the airway pressure drop during the first 100 ms when the airway is occluded
NIFThe maximum negative pressure generated during inspiration against an occluded airway
SuctionThis function allows breaths to be delivered with a 100% O2 concentration, before and after a tracheal suction maneuver.

20 – 120 s; Resolution: 10

O2 100%Delivers O2 100% for 2 minutes
StandbyPlaces ventilator in standby mode
SighBreaths delivered at a regular interval, with a higher than normal volume or pressure.
NebulizerDuring the nebulization time, the nebulizer valve opens synchronous to inspiration to provide pressure for an external medication nebulizer
Configuration settingSighOn or off,

0 – 50% of volume or pressure setting, Resolution: 1%

Interval: 20 – 200 breaths, Resolution: 1

Sigh per time: 1 – 6 breaths, Duration: 1

NebulizerOn or off, Duration: 1- 480 min, Resolution: 1

Accuracy: ±10 s

Humidification TypeNone, HME, Warm Humidified
Compliance CompOn or Off;
Power and Gas SupplyAC input100 to 240 VAC (47 – 63 Hz)
Battery Backup  (with fully charged battery)≥120 min
High pressure oxygen inlet supply29 – 87  psi clean, dry, and oil–free medical grade
Battery specificationTypeTwo Li-Ion
Voltage, Energy14.4 V, totally >80Wh
Alarm SystemAuditory alarmInternal speakers
Visual alarmIn the TFT display
IndicatorLED
TypesTechnical, Physiological, Messages
PrioritiesHigh, Medium, Low
Environmental DataOperating temperature5 – 40 °C
Storage temperature(-10) – 60 °C
Operating Humidity15% – 95% non condensing
Storage Humidity5% – 95% non condensing
Operating altitude11,000 ft (3,500 m) above sea level
Physical DataWidth x depth x height (main case)45 x 35 x 29 cm
Weight≈12 Kg
Noise LevelTBD
DisplayTFT Size12.1” wide, with Touch screen
Pressure SafetyMaximum limited pressure110 ±10  cmH2O
Maximum operating pressure80 cmH2O
Compliance and ApprovalsClassificationsClass I equipment, Type BF, internally powered, drip–proof equipment for continuous operation

EMC related group and classification: I-B

Meets International StandardsEN 60601-1: 2006

EN 60601-1-2: 2007

EN 60601-1-8: 2007

EN 60601-2-12: 2006

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Ventilator – Medical Device”

Your email address will not be published. Required fields are marked *

Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.

Company Policies
Inquiries

General Inquiries

There are no inquiries yet.