Ventilator – Medical Device
$0.00
Pediatric through adult (20 ml Tidal volume)
12’’ color touch screen
Ergonomic design helps to do better
Use for invasive and non-invasive
Automatic set-out raspiratory parameters by IBW determination
72 hours trend storage
Smart alarm system
Capability to stay on for 2 hours with internal Battery
Automatic leak compensation
Automatic tube compensation
Modern pressure and flow trigger
Technical Specification | ||
Ventilation Modes | Assisted Control Mandatory Ventilation | CMV |
Synchronized Intermittent Mandatory Ventilation | SIMV | |
Spontaneous Ventilation | SPONT | |
Breath Types | Volume–controlled breaths | V–CMV, V–SIMV |
Pressure–controlled breaths | P–CMV, P–SIMV, PS | |
Volume Targeted Pressure–controlled breaths (Pressure Regulated Volume Control) & (Volume Support) | PRVC–CMV,PRVC–SIMV,VS | |
Dual Level PEEP breaths (Spontaneous Positive Airway Pressure) | SPAP | |
Patient Height | 42 – 250 cm | |
IBW (Ideal Body Weight ) | 5–200 Kg | |
Gender | Male, Female | |
VBS (Ventilator Breathing System) | Acceptable Compliance range | 0.5 – 5 ml/cmH2O |
Acceptable Inspiratory Resistance range | 0 – 2.5 cmH2O.s/l | |
Acceptable Expiratory Resistance range | 0 – 2.5 cmH2O.s/l | |
Apnea Backup | Settings | On (Rate, Pcontrol,Ti); OFF |
Breath triggering | Pressure triggering | (-2) – (-20) cmH2O |
Flow triggering | 2 – 20 l/min | |
Additional Setting | Respiratory Rate
Accuracy:±1 b/min or 4% wig |
2– 120 b/min |
Tidal Volume
Accuracy: For 50–2000 ml: ± (4 ml + 15% Actual reading) For 20–49 ml: ± (7 ml + 15% Actual reading) |
20 – 2000 ml
(Compliance & BTPS compensated) |
|
PEEP / CPAP
Accuracy:±12% or ±(2cmH2O +4% Actual reading) wig |
0 – 40 cmH2O | |
Pcontrol
Accuracy: ±12% or ±(2cmH2O +4% Actual reading) wig |
2 – 80 cmH2O | |
Psupport
Accuracy: ±12% or ±(2cmH2O +4% Actual reading) wig |
0 –60cmH2O | |
Peak Flow
Accuracy: ±12% or ±(3 l/min +4% Actual reading) wig |
Mandatory
3– 120 l/min Spontaneous 1 –200l/min |
|
Leak Comp
Automatic Leak Compensation |
On or Off | |
Base Flow | 4.5 – 25 l/min | |
Flow Patterns | Square, Dec, Dec 50% | |
NIV | On or Off
Non–Invasive ventilation can be enabled in all modes. |
|
I–Time (Ti)
Accuracy: ± 0.02 sec |
0.2 – 5.0 sec | |
Pause (insp plateau)
Accuracy: ±0.02 sec |
0.0 – 2.0 sec | |
Rise time | Fast, Med, Slow | |
Exhalation sensitivity
Accuracy: ±12% or ±(3 l/min +4% Actual reading) wig |
10–80 % of peak flow | |
Oxygen (FiO2)
Accuracy (Delivery): ± (3 %) full scale |
21 – 100 % | |
Nebulizer
Accuracy: ±10 s |
On or Off;
User selected duration (1–480 minutes) User selected interval (1–480 minutes) |
|
Sigh | On or Off; 0 – 50% of volume or pressure setting
Interval; 20 – 200 breaths Sighs per time: 1 – 6 |
|
Humidification Type | None, HME, Warm Humidified | |
Compliance Comp | On or Off | |
Graph Settings | Waveforms; up to 3 (flow, pressure, volume)
Loops; 1 or 2 |
|
Trend Data Settings | Up to 3 trends | |
Displayed Measurements | 6 | |
Compliance Compensation | On or Off | |
Audio/Display Settings | Audio Level
LCD Brightness |
|
SPAP Mode Settings | Phigh
Accuracy:±12% or ±(2cmH2O +4% Actual reading) wig |
5 to 50 cmH2O |
Plow
Accuracy: ±12% or ±(2cmH2O +4% Actual reading) wig |
0 to 50 cmH2O | |
Psup High
Accuracy: ±12% or ±(2cmH2O +4% Actual reading) wig Phigh + Psup High will not exceed 80 cmH2O |
0 to 75cmH2O | |
Psup Low
Accuracy: ±12% or ±(2cmH2O +4% Actual reading) wig Plow + Psup Low will not exceed 80 cmH2O |
0 to 80 cmH2O | |
Thigh
Accuracy: ±0.02 sec (Thigh+Tlow ≤ 60 sec) |
0.1 to 59.8 sec | |
Tlow
Accuracy: ±0.02 sec (Thigh+Tlow ≤ 60 sec) |
0.2 to 59.9 sec | |
Monitored / Displayed Patient Values | Pressure Values | |
Ppeak (peak pressure during a breath)
Accuracy: ±12% or ±(2cmH2O +4% Actual reading) wig |
0 – 100 cmH2O | |
PEEP (pressure at end exhalation)
Accuracy: ±12% or ±(2cmH2O +4% Actual reading) wig |
0 –100cmH2O | |
Pmean (averaged mean pressure)
Accuracy: ±12% or ±(2cmH2O +4% Actual reading) wig |
0 – 100 cmH2O | |
PendInsp
Accuracy: ±12% or ±(2cmH2O +4% Actual reading) wig |
0 – 100 cmH2O | |
Volume / Flow Values | ||
Vte (expiratory tidal volume)
Accuracy: ±(4 ml + 15% Actual reading) |
0 – 3000 ml | |
Vti
Accuracy: ±(4 ml + 15% Actual reading) |
0 – 3000 ml | |
Ve (exhaled minute volume)
Accuracy: ±12 % or ±(2 L+ 4% Actual reading) wig |
0 –99l/min | |
VeSpont (spontaneous exhaled minute volume)Accuracy: ±12 % or ±(2 L+ 4% Actual reading) wig | 0 –99l/min | |
Leak
Accuracy: ±12 % or ±(3% + 4% Actual reading) wig |
0 – 100% | |
PF (peak inspiratory flow)
Accuracy: ±12% or ±(3 l/min +4% Actual reading) wig |
0 – 200 l/min | |
PFe (peak expiratory flow)
Accuracy: ±12% or ±(3 l/min +4% Actual reading) wig |
0 – 160 l/min | |
Time Values | ||
Rate (measured mandatory and spontaneous breaths per minute)
Accuracy: ±1 b/min or 4% wig |
0 – 150 b/min | |
Rate Sp.
Accuracy: ±1 b/min or 4% wig |
0 – 150 b/min | |
Inspiration Time (Ti)
Accuracy: ± 0.2 sec |
0.1 99.9 sec | |
Expiratory Time (Te)
Accuracy: ± 0.2 sec |
0.1 99.9 sec | |
I:E, calculated only | 1:99 – 99:1 | |
H:L | 1:599 – 299:1 | |
Ti/Ttot
Accuracy: ±5% or ±1 wig |
1 – 99.9% | |
Respiratory Mechanics | ||
Cstat
(static compliance, lung stiffness) Accuracy: ±10% or ±4 ml/cmH2O wig |
0 – 250ml/cmH2O | |
Cdyn
(Dynamic compliance) |
0 – 250 ml/cmH2O | |
Rinsp
(resistance of airways and tubes) |
0 – 1000 cmH2O/l/sec | |
Rexp
(Expiratory resistance) |
0 – 1000 cmH2O/l/sec | |
Auto PEEP (Actual PEEP – set PEEP)
Accuracy: ±12% or ±(2cmH2O +4% Actual reading) wig |
0 – 100 cmH2O | |
Pplateau
Accuracy: ±12% or ±(2cmH2O +4% Actual reading) wig |
0 – 100 cmH2O | |
RSBI
(Measured breathing rate divided by Insp tidal volume) (RR/Vt = RSBI) Accuracy: ±10% or ±40 b/min/l wig |
0 – 3000 b/min/l | |
O2
Accuracy (Delivery): ±3 % Response time < 30 s |
15 – 103% | |
P0.1
(The maximal slope of the airway pressure drop during the first 100 ms when the airway is occluded.) Accuracy: ± (2 cmH20 + 4%) |
-30 – 0 cmH2O | |
NIF
(The maximum negative pressure generated during inspiration against an occluded airway) Accuracy: ± (2 cmH20 + 4%) |
-60 – 0 cmH2O | |
P0.1/NIF | 0 – 100 % | |
WOBimp
(Work of breathing) Accuracy: ± 10% Actual reading |
0 – 20 j/l | |
RCe
(Expiratory time constant) |
0 – 99.9 Sec | |
C20/C
(Compliance ratio) |
0.00 – 5.00 | |
Real Time Curves | ||
Pressure + Time , Flow + Time , Volume + Time | Pressure over time, Flow over time, Volume over time | |
P–V Loop, F–V Loop | Pressure–volume loop, Flow–volume loop | |
Performing Procedures | Inspiration-Hold | Pause the ventilator at end inspiration
Maximum allowable duration shall be 20 sec |
Expiration-Hold | Pause the ventilator in expiration
Maximum allowable duration shall be 20 sec |
|
Manual Breathing | Delivery a mandatory breath during the next expiratory breath in all mode | |
P0.1 | The maximal slope of the airway pressure drop during the first 100 ms when the airway is occluded | |
NIF | The maximum negative pressure generated during inspiration against an occluded airway | |
Suction | This function allows breaths to be delivered with a 100% O2 concentration, before and after a tracheal suction maneuver.
20 – 120 s; Resolution: 10 |
|
O2 100% | Delivers O2 100% for 2 minutes | |
Standby | Places ventilator in standby mode | |
Sigh | Breaths delivered at a regular interval, with a higher than normal volume or pressure. | |
Nebulizer | During the nebulization time, the nebulizer valve opens synchronous to inspiration to provide pressure for an external medication nebulizer | |
Configuration setting | Sigh | On or off,
0 – 50% of volume or pressure setting, Resolution: 1% Interval: 20 – 200 breaths, Resolution: 1 Sigh per time: 1 – 6 breaths, Duration: 1 |
Nebulizer | On or off, Duration: 1- 480 min, Resolution: 1
Accuracy: ±10 s |
|
Humidification Type | None, HME, Warm Humidified | |
Compliance Comp | On or Off; | |
Power and Gas Supply | AC input | 100 to 240 VAC (47 – 63 Hz) |
Battery Backup (with fully charged battery) | ≥120 min | |
High pressure oxygen inlet supply | 29 – 87 psi clean, dry, and oil–free medical grade | |
Battery specification | Type | Two Li-Ion |
Voltage, Energy | 14.4 V, totally >80Wh | |
Alarm System | Auditory alarm | Internal speakers |
Visual alarm | In the TFT display | |
Indicator | LED | |
Types | Technical, Physiological, Messages | |
Priorities | High, Medium, Low | |
Environmental Data | Operating temperature | 5 – 40 °C |
Storage temperature | (-10) – 60 °C | |
Operating Humidity | 15% – 95% non condensing | |
Storage Humidity | 5% – 95% non condensing | |
Operating altitude | 11,000 ft (3,500 m) above sea level | |
Physical Data | Width x depth x height (main case) | 45 x 35 x 29 cm |
Weight | ≈12 Kg | |
Noise Level | TBD | |
Display | TFT Size | 12.1” wide, with Touch screen |
Pressure Safety | Maximum limited pressure | 110 ±10 cmH2O |
Maximum operating pressure | 80 cmH2O | |
Compliance and Approvals | Classifications | Class I equipment, Type BF, internally powered, drip–proof equipment for continuous operation
EMC related group and classification: I-B |
Meets International Standards | EN 60601-1: 2006
EN 60601-1-2: 2007 EN 60601-1-8: 2007 EN 60601-2-12: 2006 |


MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
General Inquiries
There are no inquiries yet.
Reviews
There are no reviews yet.